ACL series Magnetic Level Gauge take float as measuring element. Magnetic steel drives column display, not requiring energy. ACL is suitable for varies environment from Low to high temperature, from vacuum to high pressure, which is ideal level measuring instrument for Petrochemical Industry and etc.
ACL can realize remote alarm and limit control, configuring upper and lower limit switch output.
ACL can realize distance instruction, testing and control of level, configuring transmitter.
We provide Side-Mounted and Top-Mounted according to installation site in the container.
We provide stainless steel, PP plastic, stainless steel lining teflon etc. according to medium. PP plastic and stainless steel lining teflon are ideal for acid and alkali corrosive medium.
1.Basic Model
Float moves up and down with the elevation of level in the measuring tube, based on the principle of buoyancy. Permanent magnet steel in the float drives the red and white column roll over 180°by Magnetic Coupling effect. The column turns from white to red when the level rise, conversely, the column turns from red to white. Thus the level indication is realized.
2.Upper and Lower Limit Switch Output
The alarm switch on the set position of standpipe acts according to the magnetic float moving with the elevation of level. Thus it can realize ON-OFF control or alarm.
3.Electrical Remote Transmission
Transmitter is mounted on the magnetic level meter. The transmitter consists of sensor and transducer. It moves up and down the magnetic sub measurement measuring element followed by action role within the catheter by the magnetic coupling resistance signal change converts the standard 4 ~ 20mA current signal output, so that the digital display instrument or computer connection, Remote Display.
Installation | Side-Mounted | Top-Mounted | ||
Installation Interval | Stainless Steel | 500-12000mm | 500-2500mmm | |
PP | 500-4000mm | |||
Working Pressure | 0.6、1.6、2.5、4.0MPa | 0.6、1.6、2.5、MPa | ||
Medium Density | ≥0.6g/cm3 | ≥0.76g/cm3 | ||
Flange | Stainless Steel | 20-40(DN20、PN4.0)
(GB/T9119-2000) |
200-25(DN200、PN2.5)
(GB/T9119-2000) |
|
PP Plastic | 20-10(DN20、PN1.0)
(GB/T9119-2000) |
200-6(DN200、PN0.6)
(GB/T9119-2000) |
||
Body Material | PP Plastic, Stainless Steel | |||
Medium Temperature | -40~80℃ 0~150℃ 0~300℃(PP Plastic -10~60℃) | |||
Ambient Temperature | -40~70℃ | |||
Indication Error | ±10mm | |||
Medium Viscosity | ≤0.07Pa.S | |||
Upper and Lower Limit Switch Output | Sensitivity Control:10mmOutput Contact Capacity:AC220V0.5A
Transducer:AC220V5A Contact Life:50000 |
|||
Electrical Remote Transmission Continuous Display | Accuracy:±1.5%Output Load:4-20mA时 0-500Ω
Signal Output:DC4-20mA,Two-wire system Explosion-proof: iaⅡCT4 Intrinsically Safe |
Note: 1. Side-Mounted:
Stainless Steel: Measuring Range= Installation Space
PP: Indication Range= Installation Space L- 150mm
2. Installation Space (Measuring Range) Size: 500-5000mm (belonging to special orders design if longer than 5000mm)
ACL Magnetic Level GaugeACL Insulation jacket Magnetic Level Gauge | Structure Characteristics | ||||||||
|
1 |
Side-Mounted |
Installation |
||||||
2 |
Top-Mounted | ||||||||
1 | PP Plastic(suit for≤0.6MPa) |
Body Material |
|||||||
2 | 1Cr18Ni9Ti 0Cr19Ni9(304) | ||||||||
3 | Stainless Steel lining PTFE | ||||||||
1 |
0.6MPa |
Nominal Pressure |
|||||||
2 |
2.0MPa | ||||||||
3 |
2.5MPa | ||||||||
4 |
4.0MPa | ||||||||
5 |
High-Pressure 9.6MPa | ||||||||
1 | Basic Model |
Control Function. |
|||||||
2 | Upper and Lower Limit Switch Output | ||||||||
3 | Electrical Remote Transmission(4-20mAOutput,24VDC) | ||||||||
4 | Intrinsically Safe Remote(4-20 mAOutput,24VDC) | ||||||||
L | =Installation Space(Measuring Range) |
Measurement Index |
|||||||
L1 |
Installation Depth(Top-Mounted)0-3000mm Optional | ||||||||
Medium Density | (g/cm3) | ||||||||
ACL- |
0 |
A |
1 |
1 |
L= | L1= | ρ= |
Example |
Model Example
ACL-1111 L=2500 ρ=0.6
Side-Mounted,PP Plastic,0.6MPa,Basic Model,Installation Space(Measuring Range):2500mm Medium Density: 0.6g/cm3
1.Upper and Lower Switch Output
Consist of reed switch and transducer with holding action, reed switch and transducer are respectively mounted in the site and control room, three pairs of contact switch (AC220V 5A).
2.Electrical Remote Transmission
Consist of measuring unit and transducing unit.
1. Specializing in the field of measurement for 16 years
2. Cooperated with a number of top 500 energy companies
3. About ANCN:
*R&D and production building under construction
*Production system area of 4000 square meters
*Marketing system area of 600 square meters
*R&D system area of 2000 square meters
4. TOP10 pressure sensor brands in China
5. 3A credit enterprise Honesty and Reliability
6. National "Specialized in special new" little giant
7. Annual sales reach 300,000 units Products sold worldwide
If the product shape and performance parameters have special requirements, the company provides customization.